Technical Resources

Specs, fire ratings & sizing.

Panel properties, fire-resistance ratings, and how we size a panel to your span. Figures are preliminary and will be confirmed at Canadian Construction Materials Centre (CCMC) evaluation.

Sizing

Tell us the span. We’ll tell you the depth.

How far a DLT panel spans is not one number. It moves with panel depth, the load it carries, the deflection limit the project works to, whether the panel runs continuous over an intermediate support, and — on floors — whether footfall vibration governs before deflection does. A published table has to guess at all five. We would rather ask.

What sets the span

Depth

2×4 to 2×12 lamella, 89 to 286 mm. The biggest lever by a wide margin.

Load

Roof snow for your location including drift, or floor live load for the actual occupancy.

Deflection and vibration

The limit the project is designed to. On floors, vibration often governs a long span before deflection does.

Continuity

A panel that runs continuous over an intermediate support reaches meaningfully further than one stopping at each end.

Send us five things and we’ll come back with a depth

  • Grid and support spacing

  • Roof or floor, and the occupancy

  • Location, for snow load

  • Whether the soffit is exposed

  • Any depth or build-up constraint you’re working to

Early-stage sizing is quick and free — most come back the same day. We would rather help you land on the right depth than have you design to a table.

Full span tables, engineer-confirmed on a CSA O86 basis, will be published as soon as they are ready.

Fire Performance

Fire-resistance ratings.

Assembly

Char Rate

Sacrificial Depth

Fire-Resistance Rating

2×6 exposed (140 mm)

0.80 mm/min

55 mm

60 min

2×8 exposed (184 mm)

0.80 mm/min

79 mm

90 min

2×12 exposed (286 mm)

0.80 mm/min

103 mm

120 min

2×12 + ⅝-inch (15.9 mm) Type X gypsum board

Protected

—

160 min

Calculated per the CSA O86 zero-strength-layer method: char at 0.80 mm/min, the CSA O86 rate for mechanically laminated timber, plus a 7 mm zero-strength layer. Each ⅝-inch Type X gypsum layer adds 40 minutes. Rated floors and roofs also need a protective top layer, such as plywood, OSB or a concrete topping. Preliminary: residual section capacity must be confirmed by project engineering for the project’s loads.

Physical Properties

Panel specifications.

Property

Value

Lamella species

SPF (spruce-pine-fir), No.2 & Better

Dowel species

Hard maple

Maximum panel width

12 ft (3,660 mm)

Maximum panel length

60 ft (18,288 mm)

Panel depth range

3½ – 11¼ in (89 – 286 mm) · 2×4 to 2×12 lamella

Mean density

≈ 470 kg/m³

Service moisture content

12% ± 2%

Specified bending strength (fb)

11.8 MPa · CSA O86

Thermal conductivity

0.12 W/m·K

Reaction to fire

Exposed mass timber, no coatings

Typical values for Engrained DLT. Final certified values will be published following Canadian Construction Materials Centre (CCMC) evaluation.

Documentation

Get the full documentation pack.

The full panel spec sheet and our fire-resistance calculations — sent to your inbox. You’ll also be first to know at CCMC evaluation and production launch.

One email with the documents, plus occasional launch updates. No spam, unsubscribe anytime.

Panel spec sheet

Included · PDF

Fire-resistance calculations

Included · PDF

Sizing enquiry

Same-day response

Get Started

Specifying DLT on a project?

Send us your loads, spans, and fire requirements — we’ll return sized options and the supporting documentation.

Ontario, Canada · Est. 2025