Technical Resources

Specs, spans & fire ratings.

Everything you need to specify Dowel Laminated Timber — panel span tables, fire-resistance ratings, and physical properties. Figures are preliminary and will be confirmed at Canadian Construction Materials Centre (CCMC) evaluation.

Span Guide

Panel span tables.

Lamella (on edge)

Panel depth

Roof · 0.5 kPa

Floor · 1.9 kPa

Floor · 4.8 kPa

2×4

89 mm

3.6 m

2.9 m

2.2 m

2×6

140 mm

5.8 m

4.7 m

3.6 m

2×8

184 mm

7.9 m

6.4 m

4.9 m

2×10

235 mm

9.8 m

8.1 m

6.2 m

2×12

286 mm

11.6 m

9.6 m

7.4 m

Preliminary allowable clear spans for single-span DLT panels at deflection limit L/300. Confirm final spans with project engineering.

Fire Performance

Fire-resistance ratings.

Assembly

Char Rate

Sacrificial Depth

Fire-Resistance Rating

2×6 exposed (140 mm)

0.65 mm/min

46 mm

60 min

2×8 exposed (184 mm)

0.65 mm/min

66 mm

90 min

2×12 exposed (286 mm)

0.65 mm/min

85 mm

120 min

2×12 + ⅝-inch (15.9 mm) Type X gypsum board

Protected

180 min

Calculated per the CSA O86 zero-strength-layer method: char at 0.65 mm/min plus a 7 mm zero-strength layer. Preliminary — residual section capacity must be confirmed by project engineering, and ratings will be confirmed by testing at certification.

Physical Properties

Panel specifications.

Property

Value

Lamella species

SPF (spruce-pine-fir), machine stress-graded

Dowel species

Maple / birch hardwood, kiln-dried

Maximum panel width

12 ft (3,660 mm)

Maximum panel length

60 ft (18,288 mm)

Panel depth range

3½ – 11¼ in (89 – 286 mm) · 2×4 to 2×12 lamella

Mean density

≈ 470 kg/m³

Service moisture content

12% ± 2%

Specified bending strength (fb)

11.8 MPa · CSA O86

Thermal conductivity

0.12 W/m·K

Reaction to fire

Exposed mass timber, no coatings

Typical values for Engrained DLT. Final certified values will be published following Canadian Construction Materials Centre (CCMC) evaluation.

Documentation

Get the full documentation pack.

Span tables, the fire-resistance report, and the full panel spec sheet — sent to your inbox. You’ll also be first to know at certification and production launch.

One email with the documents, plus occasional launch updates. No spam, unsubscribe anytime.

Span & load tables

Included · PDF

Fire-resistance report

Included · PDF

Panel spec sheet

Included · PDF

Get Started

Specifying DLT on a project?

Send us your loads, spans, and fire requirements — we’ll return sized options and the supporting documentation.